data logging and telemetry systemThe microSpider lite is an economical self-contained data logging and telemetry system. It includes all software, hardware, batteries and a built-in mobile phone module. The compact waterproof (IP-68) enclosure makes it suitable for installations in the toughest environments.

microSpider lite is ideal for simple applications such as metering, tank monitoring and level monitoring.

No software is required on your computer to set up or interrogate a microSpider lite.

The microSpider lite can:

  • monitor inputs (analogue, digital, counters, frequency, quadrature/shaft encoder)
  • generate SMS, email and twitter alarms
  • record data
  • send reports via e-mail, FTP or HTTP
  • communicate via internal 3G/4G or LTE Cat M1 modem
  • be used in wet environments
  • operate for more than 5 years on its replaceable internal battery
  • update software automatically in-field from remote servers, or update from connected PC.

The microSpider lite is ideal for short and long-term monitoring. It can interface with a wide range of sensors and meters. The browser interface makes it easy to set up and test, and there is no need for external power, batteries or solar panels.

The "M" variant features even lower power consumption by utilising the latest LTE Cat M1 communication technology.
microSpider lite can communicate over private networks as used by large government and commercial entities.

Once installed the microSpider lite will log data and automatically send reports directly to the end user via e-mail, FTP or HTTP.
No specialised web portals or software subscriptions are required.

User configurable alarms can send SMS, e-mail and twitter alarm messages and automatically initiate sending of data reports.

Note: A LANlink Cable (sold-separately) is required to connect the microSpider lite to a computer for configuration via the built-in web server.


Economical – low upfront, installation and operational costs

Easy to use – simple familiar web browser interface

Easy to install

Internal batteries - no external batteries, power supplies or solar panels

Integrated mounting – bolt straight to wall

Waterproof enclosure – no need for extra enclosures

Can be managed remotely using SMS commands or FTP server

No special software required

setup and download using browser

reports sent straight to your PC or server

text/csv reports open in Excel

receive reports via email, FTP or HTTP

No licenses, royalties or service agreements

Large internal memory – full local backup of data


Physical

Dimensions: (approx) 165(W) x 80(H) x 85 (D) mm

Weight: (approx) 800 g

Enclosure: ABS rated IP - 68 with integrated mounting

Operating temperature: -5 to +50 degrees Celsius

Data Recorder

Capacity: approximately 400,000 records

Storage memory: Non-volatile FLASH

Time resolution: 1 second

Download format: CSV file

Battery

Integrated long life lithium batteries (up to 10 years battery life depending on application)

Warranty

Factory backup 12 months parts and labour guarantee


Inputs

Number of inputs:

  • 2 digital
  • 2 analog
  • 4 system inputs
  • Up to 8 Modbus (with factory RS-485 interface option)

Digital Inputs:

  • 0 - 12V DC Voltage or voltage-free switch contact
  • Can be used as switch, event (rainfall), counter or utility meter inputs (user selectable)

Analogue Inputs: Resolution 12 bits

  • 4 - 20 mA, common ground
  • 0 - 2.4V, common ground
  • 0 - 5V, common ground
  • 0 - 10V, common ground

Counter / Event Inputs

  • Minimum pulse width: 5 ms
  • Maximum frequency: 100 Hz
  • Range: 0 - 999,999

System Inputs:

  • System temperature
  • Battery voltage
  • LAN power voltage
  • Internal moisture sensor

Outputs

Number of outputs 2

  • 1 x Open collector for accessory control
  • 1 x Low power sensor supply (3.3V or 5V)

Alarms

Number of alarms: 16

Type: SMS, twitter and/or e-mail transmission

Trigger: User definable input and trigger point

SMS / e-mail / twitter text: 1 per alarm, user definable

Number of phone numbers: 3 per alarm, user definable

Number of e-mail addresses 3 per alarm, user definable

Communication Interfaces

Ethernet 10 base-T, RJ-45 connector on comms cable

Cellular phone module: Built-in 4G/3G or LTE Cat M1

Antenna: internal antenna - standard, external antenna - option

Internet connectivity: 4G, 3G, LAN (with LANlink cable)


Product is available in a variety of configurations to suit your needs, you may specify any of the following:

  • Internal Modbus RS-485 interface
  • Internal or external antenna
  • 3G/4G or LTE Cat M1
  • Connector or Flying Lead for input
  • DNP3
    Compliant with Level 2 of the DNP3 standard, supporting all of the microSpider2's inputs and controls, the DNP3 option allows the microSpider2 to communicate with a SCADA system via 3G/4G modem or local area network.

microSpider Battery

LANlink Cable (required to connect microSpider2 Environmental to a computer)

SDI-12/Modbus Interface

Software

microSpider Lite Software v1.95 (Zip)

microSpider Lite Modbus RS-485 Software v1.95 (Zip)

microSpider Lite Digital Software v1.95 (Zip)

Manuals / Brochures

microSpider Lite Brochure

microSpider Lite Quick Start Guide

microSpider2 Manual V1.26

Instructional Videos

Installing the O-ring

DNP3

microSpider2 Device Profile

microSpider2 XML Device Profile (Zip file)


News

GPRS Static IP addresses for remote monitoring & data-logging

Sydney, NSW 8th October 2012

As a result of recent changes made by Australia’s mobile phone carriers, Halytech can now offer its Spider range of data-loggers with a GPRS static IP address. This is a major breakthrough for remote monitoring in Australia.

Read more ...

Contact Us

Unit 11, 22 Lexington Drive
Norwest Business Park
Bella Vista NSW 2153

9:00 - 5:00 Monday to Friday

phone +61 2 8814 5235

This email address is being protected from spambots. You need JavaScript enabled to view it.

This email address is being protected from spambots. You need JavaScript enabled to view it.